2-Channel Particle Counter
CLiMET CI3100-RS TRIDENT
Real Time Monitoring in critical areas
- Stainless steel enclosure, VHP compatible
- PoE, Wi-Fi, A/C configuration available
- Large Sample Memory Buffer
- Luminous Ring for visible alerts
Contact us to learn more about the CLiMET CI3100-RS Trident
Aerosol Generator
CLiMET CI3100-RS TRIDENT
The Trident RS particle counter is a 2-channel particle counter used in continuous monitoring applications in a variety of industries – generally Grade A or B (ISO 5) biopharmaceutical or medical device clean zones. The standard particle sizes are 0.5 µm and 5.0 µm. Designed for fixed continuous monitoring applications with an external vacuum pump, the CI-3100 Trident RS offers a standard flow rate of 1 CFM.
The Trident RS Series is provided with your choice of Power-over-Ethernet (POE) or 24 VDC power.
The CI-3100 Trident RS is compatible with either POE or POE+. This technology injects power and ground into standard network cabling, eliminating the need for wall power. POE is a highly sought after technology given safety protocols of some of the largest pharmaceutical and biotech producers. Sample data is provided to end-users with a choice of either Ethernet Modbus, or Push to FTP CSV file upload; and the Trident model connects to existing network infrastructure. The sample data output is 21 CFR Part 11 compliant, and can be easily uploaded into standard environmental monitoring systems including LIMS software.
The Trident RS employs new proprietary diagnostics. Climet particle counters have a well known reputation in the industry for providing the lowest out-of-tolerance (OOT) rates on interval calibrations, which are an order of magnitude less than our competitors. Our new patented diagnostic routines provide a much higher level of failure detection against contaminated laser optics, and laser failure, which further reduces the probability of having to conduct a failure investigation.
Aerosol Generator
CLiMET CI3100-RS TRIDENT
Technical specifications
- Stainless steel enclosure, VHP compatible
- PoE, Wi-Fi, A/C configuration available
- Large Sample Memory Buffer
- Luminous Ring for visible alerts
Flow Rate Control: | Critical orifice @ 1.0 cfm (please contact us for other flow requirements) |
External Vacuum | 15” Hg minimum |
Particle Channel Sizes | 2 channels 0.5/5 μm (please contact us for other size requirements) |
Laser Diode | Optimal balance of long life, stability, and resolution for added accuracy |
Cleaning | Compatible with common cleaning and sterilization procedures, including VHP |
RH/Temp output | Compatible with RH/Temp probe |
Accessories Included | IQ/OQ Docs, manual, USB cable, mounting bracket and Quick Start Guide |
Other Accessories Available | stainless steel isokinetic probes, tubing, probe stands, software, validation documentation, customized cabling, power injector, zero count filters and other accessories sold separately. |
Alarms | Front Panel LEDs, Light Ring, and output for the CLiMET Trident Light Tower |
Other Accessories Available | stainless steel isokinetic probes, tubing, probe stands, software, validation documentation, customized cabling, power injector, zero count filters and other accessories sold separately.
|
LED Status Indicators | Power, Sample, Alarm, Count, Laser Status, Flow Status, Network FTP, Network Time, Service required and Network Link |
Environmental | Operating temperature: 0-37.8⁰ C, 32-100⁰ F Dimensions: 6.4” (W) x 4”(H) x 5.9”(D) (16.26 cm x 10.16 cm x 14.99 cm) 0-95% relative humidity, non-condensing |
Compliance | ISO 21501-4; ISO 14644-1; EU GMP, Annex 1; and FDA 21 CFR Part 11 |